- Products Details
Quick Details
-
Brand Name: BSD
Model Number: 3TF
Place of Origin: China, Huangshan
Specifications
Product Description
Application
3TF series AC Contactors are suitable in electrical system with AC 50/60Hz, rated operational voltage up to 660V, In AC-3 usage, rated operational voltage up to 380V, rated operational current up to 630A to make or break remote motors or system. They can form electromagnetic starters with suitable thermal overload relays 3UA series to protect system and motors against overload or phase-failure. They are made according to IEC60947-4.
The contactor is a straight motion mechanism having double-breaking contacts. The auxiliary contacts are arranged 2NO, 2NC at most. It is employed the flexible locking connection between the contact support and core. There are no arc-isolated panel in the le≤ 22A contactors. In the In≥ 32A contactors, there are moulded arc-chute with arc-isolated panel. Because all contacts are made of high non-fusibility and against corrosion silver alloy. All series products can be mounted by screws, le≤ 32A contactor also by installation rail.
3TF series AC Contactors are suitable in electrical system with AC 50/60Hz, rated operational voltage up to 660V, In AC-3 usage, rated operational voltage up to 380V, rated operational current up to 630A to make or break remote motors or system. They can form electromagnetic starters with suitable thermal overload relays 3UA series to protect system and motors against overload or phase-failure. They are made according to IEC60947-4.
The contactor is a straight motion mechanism having double-breaking contacts. The auxiliary contacts are arranged 2NO, 2NC at most. It is employed the flexible locking connection between the contact support and core. There are no arc-isolated panel in the le≤ 22A contactors. In the In≥ 32A contactors, there are moulded arc-chute with arc-isolated panel. Because all contacts are made of high non-fusibility and against corrosion silver alloy. All series products can be mounted by screws, le≤ 32A contactor also by installation rail.
Type | Rated thermal current (A) | Rated operation current (A) | Controllable power of motor (KW) |
Type of auxiliary contact | ||||
AC-3 | AC-4 | |||||||
380V | 660V | 380V | 660V | 380V | 660V | NO NC 1NO+1NC 2NO+2NC |
||
3TF30 | 20 | 9 | 3.33 | 1 | 5.5 | 1.4 | 2.4 | |
3TF31 | 20 | 12 | 4.33 | 5.5 | 7.5 | 1.9 | 3.3 | |
3TF32 | 30 | 18 | 7.77 | 7.8 | 11 | 3.5 | 6 | |
3TF33 | 30 | 22 | 8.5 | 11 | 11 | 4 | 6.6 | |
3TF34 | 45 | 32 | 15.6 | 15 | 23 | 7.5 | 13 | |
3TF35 | 45 | 38 | 18.5 | 18.5 | 23 | 9 | 15.5 | |
3TF40 | 20 | 12 | 4.3 | 5.5 | 7.5 | 1.9 | 3.3 | 2NC+2NO 4NC+4NO |
3TF41 | 20 | 9 | 3.3 | 4 | 5.5 | 1.4 | 2.4 | |
3TF42 | 30 | 16 | 7.7 | 7.5 | 11 | 3.5 | 6 | |
3TF43 | 30 | 22 | 8.5 | 11 | 11 | 4 | 6.6 | |
3TF44 | 45 | 32 | 15.6 | 15 | 23 | 7.5 | 13 | |
3TF45 | 45 | 38 | 18.5 | 18.5 | 23 | 9 | 15.5 | |
3TF46 | 70 | 45 | 24 | 22 | 39 | 12 | 20.8 | |
3TF47 | 70 | 63 | 28 | 30 | 55 | 14 | 24.3 | |
3TF48 | 90 | 75 | 34 | 37 | 67 | 17 | 29.3 | |
3TF49 | 90 | 85 | 42 | 45 | 67 | 21 | 36 | |
3TF50 | 150 | 110 | 54 | 55 | 100 | 27 | 46.9 | |
3TF51 | 150 | 140 | 68 | 75 | 100 | 35 | 60 | |
3TF52 | 180 | 170 | 75 | 90 | 156 | 38 | 66 | |
3TF53 | 220 | 205 | 96 | 110 | 156 | 50 | 86 | |
3TF54 | 300 | 250 | 110 | 132 | 235 | 58 | 100 | |
3TF55 | 300 | 300 | 125 | 160 | 235 | 66 | 114 | |
3TF56 | 400 | 400 | 150 | 200 | 375 | 81 | 140 | |
3TF57 | 550 | 475 | 150 | 250 | 375 | 81 | 140 | |
3TF68 | 630 | 630 | 600 | 335 | 560 | 160 | 2 |
Verified Supplier - huangshan safety electrical technology co.,ltd
Bussiness Type: Manufacturer,Trading Company